Appendix C– DTR Remote M&C Protocol CG-6073 (Rev R, Jun, 2012)
36
OSC FREQ (OPTIONAL-Depending on RF Range)
Path: / CONFIGS BANDS BAND-3 OSC-FREQ
Type: Data Editor
Syntax: OSC-FREQ [= n] | [D]
Range: Real: 100.000 .. 15000.000
Notes: LOCAL OSCILLATOR of the BDC that supports this band. Typical configurations:
S-band = 3750MHz
C-band = 5150MHz
X-band = 6300MHz
Ku-lo-band = 9750MHz
Ku-hi-band = 10750MHz
Ka-A = 16500, Ka-B = 17150, Ka-C = 18250, Ka-D = 19250, Ka-E = 20250
OSC FREQ (OPTIONAL-Depending on RF Range)
Path: / CONFIGS BANDS BAND-4 OSC-FREQ
Type: Data Editor
Syntax: OSC-FREQ [= n] | [D]
Range: Real: 100.000 .. 15000.000
Notes: LOCAL OSCILLATOR of the BDC that supports this band. Typical configurations:
S-band = 3750MHz
C-band = 5150MHz
X-band = 6300MHz
Ku-lo-band = 9750MHz
Ku-hi-band = 10750MHz
Ka-A = 16500, Ka-B = 17150, Ka-C = 18250, Ka-D = 19250, Ka-E = 20250
POL INPUTS (v1.19.08 or later)
Path: /CONFIGS MEMORY CALIBRATION OPTIONS POL-INPUTS
Type:
Data Editor
Syntax: POL-INPUTS [= n] | [D]
Range: Integer: 0 .. 1
0 Standard
1 4 Ports
Notes: 4 Ports is an optional hardware configuration that provides four discreet inputs for a
single band. Selecting the 4 inputs option will provide for POL inputs 1..4 in the POL
SELECT menu. Default is STANDARD. Select 4 Ports ONLY if the correct hardware
is installed.