13
3. Adjust the table angle manually until it is set to
90 degrees by making sure there is no space bet-
ween the square and the blade or the table. To
allow for more or less table tilt, adjust the height of
the stop bolt until the head of the bolt just makes
contact with the frame of the saw when the table is
at 90 degree to the blade .
4. With the table set to 90 degree and the stop bolt at
the correct height, make sure the angle indicator
pointer is set to read 0 degrees . If the pointer
needs to be adjusted loosen the screw , adjust the
pointer to the 0 point on the scale and re-tighten
the screw to secure the pointer in place.
5. With the stop bolt set to the correct height and the pointer position properly aligned, tighten the jam nut (Refer
back to step 1) to secure the stop bolt in place. You will now be able to accurately return the table to the
90 degree position automatically without further adjustments and scale reading for any angle other than 0 will
be accurate.
Before replacing or adjusting the blade, make sure the switch is in the “OFF” position and that the power cord is unplugged.
REMOVING/INSTALLING THE BLADE
BLADE CLEARANCE
Note: When performing blade installation, removal, ten-
sionning or tracking, maximum clearance between the
blade and both upper and lower bearing assemblies is
required to minimize friction, which would be damaging
to the blade.
Proceed as follows: Loosen the bolt
.
Then push on the
bearing assembly shaft going back as far as possible
for maximum blade clearance. Tighten the bolt to lock the
bearing assembly in place.
Repeat with lower bearing assembly.
1. Release blade tension by turning the blade tension
adjustment handwheel counter-clockwise until
it stops.
2. Remove the table aligning pin.