BRAIN 17 25 732788 - Rev. A_1
ENGLISH
Display Advanced Function
Default
PF
PRE-FLASHING:
You can enable/disable the pre-flashing. Pre-flashing duration = 3 sec.
Y = enabled before each movement
no = disabled
no
EC
ANTI-CRUSHING SENSITIVITY (visualised only with the function En
=
Y):
Varying this function varies the amount of time after which, in case of obsta-
cle, the board commands reversal of the leaves, or it will command a stop
if the leaves are in the contact point search space (see the parameter
rB).
The fourth consecutive obstacle detected in the same direction and position
will be defined as a contact point and the leaf will stop in that position.
00 = minimum sensitivity (maximum time before reversal)
10 = maximum sensitivity (minimum time before reversal)
05
r8
MECHANICAL STOP SEARCH ANGLE (displayed only if function En =
Y and functions Fc and FA = no or = 02):
You can adjust the contact point search angle within which the board will stop
movement without reversing, if it encounters an obstacle or the contact point.
Adjustable in two modes:
01 = Low contact point search space (about 1 degree)
02 = High contact point search space (about 4 degree)
02
SP
OUTPUT WL:
You can set the output W.L. (open collector N.O.) in one of the following
functions:
00 = INDICATOR LIGHT (OFF = closed, ON = during opening and open/
pause, FLASHING = during closing)
01 = COURTESY LIGHT (fixed time 90 seconds)
00