24
GB
2.4 Battery handling
• Only insert batteries into the charger once they have cooled down.
• GESIPA
®
batteries can be charged approx. 1000 times.
• Do not insert the battery into the charger after each use.
• ,IEDWWHU\DXWRQRP\EHFRPHVVLJQL¿FDQWO\VKRUWHUGHVSLWHSURSHUUHFKDUJLQJWKHEDWWHU\
should be replaced.
• Store batteries in a dry place where there is no danger of frost. The optimum operating
temperature range is 10°C to 50°C.
GESIPA
®
batteries have a display showing battery life in percent. Press the button in the
display to activate the green LED lights for approx. 5 seconds.
*****
****
***
**
*
Battery fully charged
Battery capacity approx. 80%
Battery capacity approx. 60%
Battery capacity approx. 40%
Battery capacity max. 20%, charge soon
2.5 Environmental protection
If batteries need to be replaced, please observe the following:
• Take used GESIPA
®
batteries back to your agent or to GESIPA
®
for recycling.
• Never throw discarded batteries into the waste, into fire or into water!
3. Troubleshooting
3.1 Blind rivet cannot be set
Cause Remedy
No battery Charge battery; replace if necessary
Jaws dirty or worn Clean them and lubricate or grease the sliding surfaces
or replace them (see 1.9)
Jaw assembly loose Tighten (see 1.9)