3.2 No spent mandrel discharge
Cause Remedy
Nosepiece too small Exchange according to table (see 1.4)
Dirt inside head Clean (see 1.9)
Spent mandrel container full Take off and empty
Mandrel tube blocked Remove blocked mandrel and check for free ejection (see 1.7)
 /('OLJKWVÀDVKLQJ
Cause Remedy
No battery Change battery (see 1.7)
%OLQGULYHWLQJWRRORYHUORDGHG/('ÀDVKHV
slowly – 1 Hz)
Select rivet dimensions according to work
capacity (see 1.1; 1.7)
Blind riveting tool blocked on return (LED
ÀDVKHVIDVW±+]
Unscrew steel head sleeve and remove
blockage (see 1.9)