8.4 Storage conditions
Keep tool in a dry, frost-proof area
9. Repair
In principle, warranty repairs should only
be carried out by the manufacturer.
When warranty expires, repairs should be
carried out by trained personnel. Failure to
correctly carry out setting instructions and
incorrect handling can lead to serious tool
defects. When in doubt, the tool should be
returned to the manufacturer.
10. Troubleshooting
10.1 Blind rivet does not set
Jaws N° 15 dirty Clean and lubricate (point 8.1)
Jaws N° 15 worn Change jaws (point 8.2)
Low air pressure See air pressure requirement (point 4)
Stroke too small Refill hydraulic fluid (point 8.3)
10.2 Spent mandrel is not evacuated
Spent mandrel container full Empty spent mandrel container (point 7.5)
Wrong nosepiece in use Change according to table (Point 6)
Nosepiece worn Change nosepiece
Spent mandrel jammed in jaw housing Clean and oil jaws or change if worn
(point 8.2)
Remedy
Cause
Remedy
Cause
15
11. Warranty
This riveting tool has a 12 months warranty
from the date of delivery (to be proven by
invoice or delivery note). Damage caused
by wear, overload or improper handling is
excluded from the warranty.
Damage caused by material or manufacturing
defects will be covered by the warranty and
will be repaired or replaced free of charge.
Claims can only be accepted if the complete
riveting tool
(not dismantled)
is returned to
the distributor, or to
GESIPA.