Fitting and commissioning are to be carried out only by authorized trained personnel
in accordance with the operating instructions. These products are intended for use
exclusively with compressed air.They are not suitable for use with other media
(fluids or gases).
1 - APPLICATION
As designed, the filter control valve MS4/6-LFR and
pressure control valve MS4/6-LR(B) control the work
pressure set in the following string. The MS4/6-
LFR/LR(B) thereby smooths out: fluctuations in
pressure. The filter control valve MS4/6-LFR and
filter MS4/6-LF with centrifugal separator remove dirt
particles and condensate
2 - CONDITIONS OF USE
• Compare the maximum values specified in these
operating instructions with your actual application
(e.g.pressures, torques). Only if the loading limits are
observed can the product be operated in accordance
with the relevant safety guidelines.
• Remove dirt particles in the supply lines by blowing
out the tubing with compressed air. In this way you
will protect the device from premature failure or
heavy wear (see DIN ISO 4414, section 9.4)
• Use the product in its original state without
undertaking any modifications.
3 - FITTING MECHANICAL COMPONENTS
• Use shut-off valves in the compressed air tubing for
exhausting the system (e.g. for replacing a filter).
• Note the direction of flow from 1 to 2. The figure1on
the product housing serves as an orientation
• Place the MS4/6-LF… with sufficient space
underneath the filter bowl (min. 100 mm).
This facilitates replacing the filter cartridge.
.