48
Template Go, Version 1, 01.07.2014 / ModuleVersion 1.0
Operating the base on the PABX
Gigaset E560A / LUG GBR en / A31008-M2708-L101-1-7619 / settings_BS.fm / 7/14/16
Operating the base on the PABX
The following settings are only necessary if your PABX requires them; see the PABX user guide.
Changing the dialling mode
¤ Menu Enter digit for the dialling mode:
= tone dialling (DTMF); = pulse dialling (PD) OK
Switching temporarily to tone dialling (DTMF)
If your PABX still operates with pulse dialling (PD), but you need tone dialling for a connection
(e.g., to listen to the network mailbox), you must switch to tone dialling for the call.
Prerequisite: You are conducting a call or have already dialled an external number.
¤ Press the star key .
Tone dialling is now activated for this call only.
Setting recall
¤ Menu Enter digits for recall:
= 80 ms; = 100 ms; = 120 ms; = 400 ms; = 250 ms; = 300 ms;
= 600 ms; = 800 ms OK
Changing the pause after line seizure
You can set the length of the pause inserted between pressing the talk key and sending the
phone number.
¤ Menu Enter digit for the current pause length:
= 1 second; = 3 seconds; = 7 seconds OK
Changing the pause after recall key
¤ Menu Enter digit for the current pause length:
= 800 ms; = 1600 ms; = 3200 ms OK
Operating the telephone on a router
Operation with a router
When operating on the analogue connection of a router, potentially occurring echoes can be
reduced by switching on XES mode 1 ( XES = "eXtended Echo Suppression").
If there are no problems with echoes, the normal mode (factory settings) should be activated.
¤
¤ OK (for normal mode)
¤ OK (for XES mode 1)