3.4 Acquisition and trigger controls
3.4.1 Overview
NOTE Settings can only be changed if image acquisition is stopped.
The following commands allow to make settings required for image acquis-
ition and to control an external trigger.
Name Type Access
AcquisitionMode Enum R/W
AcquisitionStart Command WO
AcquisitionStop Command WO
AcquisitionFrameRateRaw Integer R/W
ExposureMode Enum R/W
ExposureTimeRaw Integer R/W
AcquisitionSource Enum R/W
3.4.2 Controls
AcquisitionMode
This feature controls the acquisition mode of the device. It defines the number
of frames to capture during an acquisition and the way the acquisition stops.
Actually only continuous mode is supported. In continuous mode frames are
captured continuously without stopping.
Acquisition can be stopped by an AcquisitionStop command.
Access Read / write
Interface IEnumeration
Unit --
Range Continuous
Invalidation --
Precondition CameraState = Idle
Feature description
MikrotronGmbH / mini1 / CAMMC1370/71-RG / 2021 23 - 67