IBHeight
This feature defines the height of the ImageBlitz window in units of lines.
Access Read / write
Interface Integer
Unit --
Range 1…SensorHeight-IBOffset, Inc. 1
Invalidation
Precondition CameraState = Idle or Live
IBEnable = True
IBHeight*IBWidth <=20480
IBOffsetY
This feature defines the offset of the ImageBlitz window starting from the first
sensor line, in units of lines.
Access Read / write
Interface IInteger
Unit --
Range 0…SensorHeight-IBHeight, Inc. 1
Invalidation --
Precondition CameraState = Idle or Live
IBEnable = True
IBEnable
This feature enables or disables the Mikrotron ImageBlitz feature.
Access Read / write
Interface IBoolean
Unit --
Range True, False
Invalidation IBWindowVisible
Precondition CameraState = Idle or Live
Note A transition from True->False saves the current con-
tent of the trigger ROI for the reference image.
Feature description
MikrotronGmbH / mini1 / CAMMC1370/71-RG / 2021 48 - 67