USER MANUAL
Range BEAT-Tr
Edition: January 2016
Revision: No. 3
MODE OF USE - 19
3.1.6 Entering the Operator Number: Only If Enabled (SETUP/OPERATOR = 1).
In case the operator’s ID entering is enabled, the unit allows either voluntary or
compulsory entering according to its established setup.
C Voluntary operator’s setup: it can be avoided by pressing START/VALIDATE key.
C Compulsory operator’s setup: it must be unavoidably entered.
In case of pressing START/VALIDATE key to skip it, the following message is displayed:
OPERATOR:
COMPULSORY
The message is showed up during 3 seconds.
In case the unit would be setup to carry out the operator’s traceability according to ISO
12176-3, it shall be not allowed that the operator’s identification would be carried out
manually. If done, the following message is displayed:
OPERATOR:
CONTROL ISO 12176-3
The message is showed up during 3 seconds.
If once the operator’s barcode encoding data is read and processed, some of the coded
fields are not accepted, such as the expiry date has expired, the encoded skill does not
include the electrofusion jointing or there is an error on the encoding data itself or on the
identifier, the following message is displayed:
OPERATOR:
WRONG DATA
The message is showed up during 3 seconds.
Ï
Entering Operator No. by barcode (2x5
interleaved).
OPERATOR: Start screen.
OPERATOR:
A 1234/724/SG
Capture by
scanner.
Shows the decoding of the operator number,
country and certifying organization.
To delete the reading and move to the start
screen, press <STOP>.
If the barcode or reading were incorrect:
OPERATOR:
WRONG DATA
Error message.
Two acoustic signals are emitted and it returns
to the start.
L Entering Operator No. without barcode:
via the keyboard.
Click one of the 4 arrows. The display will show
the following screen:
OPERATOR:
$---------------
Blinking cursor.
Manually enter using the arrow buttons.16
alphanumeric characters. Permitted
characters: capital letters, 0 to 9 and + . , * / -
( ) <space>.
Press the ¨ and § arrows to move the cursor
to a different field and © and ª arrows to
select the values.
To delete the reading and pass to the start
screen press <STOP>.
Press the START/VALIDATE key to pass to the next screen.