USER MANUAL
Range BEAT-Tr
Edition: January 2016
Revision: No. 3
MODE OF USE - 23
To delete the reading and move to the start
screen, press <STOP>.
Click the START/VALIDATE key to pass to the
following screen, which will correspond to
the Component 2 in the case of a coupler,
elbow, reducer or tee fitting.
COMPONENT 2: Capture by
scanner.
Now enter the traceability data of Compo-
nent 2.
PIPE PE100 9052
110 SDR17.6
The Component 2
text disappears.
The decoding is shown when the data are
entered.
To delete the reading and move to the start
screen, press <STOP>.
Enter 26 or 40 digits depending on the com-
ponent.
Click the START/VALIDATE key to show the
decoding.
PIPE PE100 9052
200 SDR11
The Component 1
text disappears.
Click the START/VALIDATE key to pass to the
following screen, which will correspond to
the Component 2 in the case of a coupler,
elbow, reducer or tee fitting.
COMPONENT 2:
Click one of the 4 arrows. The display will
show the cursor and the 40 digits with zeros.
The far right-hand side of the top line of the
display shows the digit involved.
COMPONENT 2: 01
$000000000000000000
Blinking cur-
sor.
Press the ¨ and § arrows to move the
cursor to a different field and the © and ª
arrows to select the values.
Enter 26 or 40 digits depending on the
component.
COMPONENT 2: 33
28487650020020387489
Enter data.
Click the START/VALIDATE key to show the
decoding.
PIPE PE100 9052
200 SDR11
The Component 2
text disappears.
Press the START/VALIDATE key to pass to the next screen, regardless of whether or not
the traceability data were entered.