EasyManua.ls Logo

Global BEAT-Tr - Page 23

Global BEAT-Tr
51 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
USER MANUAL
Range BEAT-Tr
Edition: January 2016
Revision: No. 3
MODE OF USE - 23
To delete the reading and move to the start
screen, press <STOP>.
Click the START/VALIDATE key to pass to the
following screen, which will correspond to
the Component 2 in the case of a coupler,
elbow, reducer or tee fitting.
COMPONENT 2: Capture by
scanner.
Now enter the traceability data of Compo-
nent 2.
PIPE PE100 9052
110 SDR17.6
The Component 2
text disappears.
The decoding is shown when the data are
entered.
To delete the reading and move to the start
screen, press <STOP>.
Enter 26 or 40 digits depending on the com-
ponent.
Click the START/VALIDATE key to show the
decoding.
PIPE PE100 9052
200 SDR11
The Component 1
text disappears.
Click the START/VALIDATE key to pass to the
following screen, which will correspond to
the Component 2 in the case of a coupler,
elbow, reducer or tee fitting.
COMPONENT 2:
Click one of the 4 arrows. The display will
show the cursor and the 40 digits with zeros.
The far right-hand side of the top line of the
display shows the digit involved.
COMPONENT 2: 01
$000000000000000000
Blinking cur-
sor.
Press the ¨ and § arrows to move the
cursor to a different field and the © and ª
arrows to select the values.
Enter 26 or 40 digits depending on the
component.
COMPONENT 2: 33
28487650020020387489
Enter data.
Click the START/VALIDATE key to show the
decoding.
PIPE PE100 9052
200 SDR11
The Component 2
text disappears.
Press the START/VALIDATE key to pass to the next screen, regardless of whether or not
the traceability data were entered.