4.6. Foreseen environmental operating conditions
The KOALA LP is designed for indoor use.
Therefore, the environmental parameters to be used as a reference are the following:
temperature between +5°C and +40°C
humidity between 30% and 95% (without condensation)
The LP’s operating environment must also meet the following requirements:
The roof of the structure must be sufficiently high so as to allow for the complete lifting of any vehicle
without causing damage.
It is recommended to verify this height when it using the lift with special vehicles.
The flooring upon which the lift is installed must be smooth and level (therefore free of any slopes and/or
roughness).
The unsuitability of the floor’s surface could lead to dangerous situations when working with the LP and
when moving the LP upon the floor while loaded.
The LP is not designed for use in environments with characteristics other than those which are described
above.
! ! ATTENTION! !
The use of the LP in environments or situations which are not
foreseen within this manual shall exonerate the company
GLOBALJIG from any responsibility regarding the use in question.
4.7. Installation characteristics
The KOALA LP must be installed upon perfectly smooth and horizontal flooring (see characteristics on page 37).
The LP must be properly fastened to the floor using the 6 supplied anchoring bolts.
In order to function properly, the LP must be connected to an external pneumatic and electrical energy supply
with the following characteristics:
Electrical power supply provided through an industrial electrical outlet, with a power supply voltage equal to
that which is required for the specific version. Specifically:
240/415 V tri-phase + ground and a frequency of 50 Hz ± 2%; the maximum foreseen consumption is
1.1 kW; the grounding wire must have a minimum cross-section of 2.5 mm²;
200/230 V tri-phase + ground and a frequency of 50/60 Hz ± 2%; the maximum foreseen consumption is
1.1 kW; the grounding wire must have a minimum cross-section of 2.5 mm²;
!!! DANGER !!!
The customer is required to install a three-pole circuit breaker, with a loss
sensitivity of 30 mA, upstream from the LP (within the building’s power panel)
in order to ensure that the power supply will be automatically cut off
in the event of an isolation failure regarding the LP itself.