www.glp.de
22 impresssion X5 User Manual
hibernation mode with a power off/on cycle, via RDM or using the Control / Settings
DMX channel. If you do this, the fixture will perform a fixture reset before returning to
normal operation.
Load User Settings
Lets you load different custom fixture configurations or return the fixture to the default
fixture settings.
To save a custom setting preset from 1 to 3, see Service
→
Advanced
→
Save_Settings.
● Load User Settings 1 to 3 loads one of three specific custom fixture settings. You
must confirm the function for 3 seconds before the new settings are loaded (see
Fixture Settings
→
Load User Settings).
● Save User Settings 1 to 3 saves the current fixture settings as a set of user settings.
You must confirm the function for 2 seconds in order to save the settings as one of
the three custom settings presets (see Service
→
Advanced
→
Save User Settings).
Note
The Load User Setting Presets and Load User Setting Defaults commands will only affect
settings in the Fixture Settings group and will not affect DMX Address, Control Mode,
Protocol Type, IP Settings, etc. This helps avoid loss of communication with the
controller.
Information
The Information submenu provides readouts of all relevant information such as the error
list if any errors have been detected, the fixture’s serial number, firmware version,
device info, device hours counter, power cycles counter, DMX input monitor, signal
quality etc.
Manual Control
This submenu gives different options for resetting the fixture manually. It can be helpful
for service or stand-alone issues.
● Reset All: Performs a full fixture reset to initialize all features and effects.
● Reset P/T: Resets pan and tilt only to initialize pan and tilt positions.
● Reset Head: Resets all the features in the head.
Manual DMX
Gives individual control of the fixture using the fixture user interface. The menu timeout
function is disabled as long this menu is open.
● Manual Control: Manually sets a DMX value for each function.
● Load No-Signal Scene: Loads the values of the captured scene stored using the
No-Signal function.