2.2 FALL PROTECTION
Operators must comply with employer, job site and governmental rules regarding
the use of personal protective equipment.
If required by your employer or job site, use personal fall protection equipment (PFPE)
when operating this machine.
All PFPE must comply with applicable governmental regulations, and must be
Inspected and used in accordance with the PFPE manufacturer’s instructions.
Fall restraint must be properly attached to a designated anchorage point when driving
or operating the machine. Attach only one fall restraint to each anchorage point.
2.3 ELECTROCUTION HAZARD
ELECTROCUTION HAZARD! THIS MACHINE IS NOT INSULATED!
DEATH OR SERIOUS INJURY will result from contact with or inadequate
clearance from any electrically charged conductor.
You must maintain a CLEARANCE OF AT LEAST 3.05 m between any part
of the machine, or its load, and any electrical line or apparatus carrying
over 300 Volts up to 50,000 Volts. 30.5 cm additional clearance is required
for every additional 30,000 Volts.
Observe Minimum Safe Approach Distance.
This machine is not electrically insulated and will not provide protection from contact with
or proximity to electrical current.
Maintain safe distances from electrical power lines and apparatus in accordance with
applicable government regulations and the following chart:
Allow for platform movement, electrical line sway or sag and beware of strong or gusty winds.
Keep away from the machine if it contacts energized power lines. Personnel on the ground or in the platform must not
touch or operate the machine until energized power lines are shut off.
Do not use the machine as a ground for welding.
13302
13303
Minimum safe distance voltage conductors
13301
Voltage
0 to 300 Volts Avoid contact
Over 300V to 50kV 3,10 m
Over 50kV to 200kV 4,60 m
Over 200kV to 350 kV 6,10 m
Over 350kV to 500kV 7,60 m
Over 500kV to 750 kV 10,7 m
Over 750kV to 1000kV 13,7 m