9.4 LUBRICATION
Operator may perform routine maintenance only. Lubrication listed as Scheduled Maintenance must be performed by
a qualified service technician.
NO ITEM SPECIFICATION FREQUENCY
1 Hydraulic
Reservoir
Mobile Fluid DTE 10, DTE 13M or
AW32.
Do not substitute other fluids as pump
damage may result.
Fill to the middle of the
dipstick with platform in the stowed posi-
tion.
Routine Maintenance
Check level daily Scheduled
Maintenance Change
yearly or every 600 hours,
whichever occurs first.
2 Hydraulic Cap
Breather Filter
Hydraulic Filter
Breather Filter
(located inside filler cap)
Hydraulic Filter Canister
Scheduled Maintenance
Normal Conditions Change every
six months or 300 hours, whichever
occurs first Severe Conditions
--very dusty, exceptionally hot or
exceptionally cold conditions Change
every three months or 150 hours,
whichever occurs first
9.4.1 LUBRICATION
13327
FULL
ADD
Maintenance