PROGRAMMING THE MONITORS
9
Locate the SW2 DIP switch on the EL632 Plus sound module of the door panel or the
EL500SE microprocessor and set to ON.
In systems with more than one door panel, only perform this procedure on the main
panel of each building.
Important: To perform this programming, the monitor's SW1 DIP switch should be set
to .OFF
Programming the TEKNA HF PLUS monitor:
M
S
SI
Continued overleaf
Turn off the monitor to be programmed (press button for 3 seconds).
Once switched off, press door release button .
Press and hold door release button and, without releasing it, switch on the
monitor (press button for 1 second).
To show that the device is ready for programming, the door
panel and monitor will emit a number of tones (the status
LED on the monitor will illuminate red), enabling door
release button to be released. To establish audio
communication with the door panel, press button .
Press the door panel button that will call this monitor.
At this moment, the door panel and monitor will emit a
number of tones (the status LED on the monitor will blink
red and the indicator LED will illuminate red.
To programme the monitor as , press button for 3 seconds (theMaster
monitor's LED will illuminate red).
To programme it as , press button once and the status LED willSlave 1
blink (green) once. Continue successively to , pressingSlave 4
button four times and the status LED will blink (green) four times.
To programme it as , press button and the LED will blinkSlave + Intercom
(green) once.
TEKNA PLUS MONITORHF