COOLING PERFORMANCE DATA
EXPANDED PERFORMANCE DATA COOLING OPERATION
MODEL: GSC130421B*/ CA*F3642*6D*
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB*Airflow 596367715963677159 63 677159 63 67715963677159636771
MBh 38.4 39.8 43.6 - 37.5 38.9 42.6 - 36.6 38.0 41.6 - 35.7 37.0 40.6 - 34.0 35.2 38.6 - 31.5 32.6 35.7 -
S/T 0.67 0.56 0.39 - 0.69 0.58 0.40 - 0.71 0.59 0.41 - 0.73 0.61 0.43 - 0.76 0.64 0.44 - 0.77 0.64 0.44 -
Delta T 19 17 13 - 20 17 13 - 20 17 13 - 20 17 13 - 19 17 13 - 18 16 12 -
1225 KW 2.69 2.76 2.86 - 2.93 3.00 3.11 - 3.14 3.22 3.34 - 3.33 3.41 3.53 - 3.48 3.57 3.70 - 3.62 3.71 3.85 -
AMPS 11.5 11.8 12.2 - 12.5 12.8 13.2 - 13.5 13.9 14.3 - 14.5 14.9 15.4 - 15.4 15.8 16.4 - 16.4 16.8 17.3 -
HI PR 148 159 168 - 166 178 188 - 188 203 214 - 214 231 244 - 241 260 274 - 267 287 303 -
LO PR 58 62 68 - 62 66 72 - 64 68 75 - 67 72 78 - 71 75 82 - 73 78 85 -
MBh 39.0 40.4 44.3 - 38.1 39.5 43.3 - 37.2 38.5 42.2 - 36.3 37.6 41.2 - 34.5 35.7 39.1 - 31.9 33.1 36.3 -
S/T 0.69 0.58 0.40 - 0.72 0.60 0.42 - 0.74 0.62 0.43 - 0.76 0.64 0.44 - 0.79 0.66 0.46 - 0.80 0.67 0.46 -
Delta T 19 17 13 - 19 17 13 - 19 17 13 - 20 17 13 - 19 17 13 - 18 16 12 -
70 1300 KW 2.74 2.80 2.90 - 2.98 3.05 3.16 - 3.19 3.27 3.39 - 3.38 3.46 3.59 - 3.54 3.63 3.76 - 3.68 3.77 3.91 -
AMPS 11.7 12.0 12.4 - 12.7 13.0 13.4 - 13.8 14.1 14.6 - 14.7 15.1 15.6 - 15.7 16.1 16.6 - 16.6 17.0 17.6 -
HI PR 150 162 171 - 168 181 191 - 192 206 218 - 218 235 248 - 245 264 279 - 271 292 308 -
LO PR 59 63 69 - 63 67 73 - 65 69 76 - 69 73 80 - 72 76 83 - 74 79 86 -
MBh 40.4 41.8 45.8 - 39.4 40.9 44.8 - 38.5 39.9 43.7 - 37.6 38.9 42.6 - 35.7 37.0 40.5 - 33.0 34.3 37.5 -
S/T 0.74 0.62 0.43 - 0.76 0.64 0.44 - 0.78 0.66 0.45 - 0.81 0.68 0.47 - 0.84 0.70 0.49 - 0.85 0.71 0.49 -
Delta T 17 15 11 - 18 15 12 - 18 15 12 - 18 15 12 - 18 15 11 - 16 14 11 -
1575 KW 2.79 2.85 2.96 - 3.03 3.11 3.22 - 3.25 3.33 3.45 - 3.44 3.53 3.66 - 3.61 3.70 3.83 - 3.75 3.84 3.98 -
AMPS 11.9 12.2 12.6 - 12.9 13.2 13.6 - 14.0 14.4 14.9 - 15.0 15.4 15.9 - 16.0 16.4 16.9 - 16.9 17.4 18.0 -
HI PR 153 165 174 - 172 185 195 - 195 210 222 - 223 239 253 - 250 269 285 - 277 298 314 -
LO PR 61 65 70 - 64 68 74 - 67 71 77 - 70 74 81 - 73 78 85 - 76 81 88 -
MBh 39.1 40.2 43.5 46.7 38.2 39.3 42.5 45.6 37.3 38.4 41.5 44.6 36.3
37.4
40.5 43.5 34.5 35.6 38.5 41.3 32.0 32.9 35.6 38.3
S/T 0.76 0.68 0.52 0.33 0.79 0.71 0.53 0.34 0.81 0.72 0.55 0.35 0.84
0.75
0.57 0.36 0.87 0.78 0.59 0.38 0.87 0.78 0.59 0.38
Delta T222117122321171223 21 171223
21
17 12 22 21 17 12 21 19 16 11
1225 KW 2.72 2.79 2.89 2.99 2.96 3.03 3.14 3.26 3.17 3.25 3.37 3.49 3.36
3.44
3.57 3.70 3.52 3.61 3.74 3.88 3.65 3.75 3.88 4.03
AMPS 11.6 11.9 12.3 12.8 12.6 12.9 13.3 13.8 13.7 14.0 14.5 15.0 14.6
15.0
15.5 16.1 15.6 16.0 16.5 17.2 16.5 16.9 17.5 18.2
HI PR 149 160 169 177 167 180 190 198 190 205 216 225 217
233
246 257 244 262 277 289 269 290 306 319
LO PR 59 63 69 73 62 66 72 77 65 69 75 80 68
72
79 84 71 76 83 88 74 79 86 91
MBh 39.7 40.8 44.2 47.4 38.7 39.9 43.2 46.3 37.8 38.9 42.2 45.2 36.9
38.0
41.1 44.1 35.1 36.1 39.1 41.9 32.5 33.4 36.2 38.8
S/T 0.79 0.71 0.53 0.34 0.82 0.73 0.55 0.36 0.84 0.75 0.57 0.37 0.87
0.77
0.59 0.38 0.90 0.80 0.61 0.39 0.91 0.81 0.61 0.39
Delta T222017122221171222 21 171223
21
17 12 22 21 17 12 21 19 16 11
75 1300 KW 2.76 2.83 2.93 3.04 3.01 3.08 3.19 3.31 3.22 3.30 3.42 3.55 3.41
3.50
3.63 3.76 3.57 3.66 3.80 3.94 3.71 3.81 3.95 4.10
AMPS 11.8 12.1 12.5 13.0 12.8 13.1 13.5 14.0 13.9 14.2 14.7 15.3 14.9
15.2
15.8 16.4 15.8 16.2 16.8 17.4 16.8 17.2 17.8 18.5
HI PR 152 163 172 180 170 183 193 202 194 208 220 229 220
237
250 261 248 267 282 294 274 295 311 325
LO PR 60 64 70 74 63 68 74 79 66 70 77 82 69
74
80 86 73 77 84 90 75 80 87 93
MBh 41.1 42.3 45.8 49.1 40.1 41.3 44.7 48.0 39.1 40.3 43.6 46.8 38.2
39.3
42.6 45.7 36.3 37.4 40.4 43.4 33.6 34.6 37.5 40.2
S/T 0.84 0.75 0.57 0.37 0.87 0.78 0.59 0.38 0.89 0.80 0.60 0.39 0.92
0.82
0.62 0.40 0.96 0.85 0.65 0.42 0.96 0.86 0.65 0.42
Delta T201915102019151120 19 151121
19
15 11 20 19 15 11 19 17 14 10
1575 KW 2.81 2.88 2.99 3.10 3.06 3.14 3.25 3.37 3.28 3.36 3.49 3.62 3.48
3.56
3.69 3.83 3.64 3.73 3.87 4.01 3.78 3.88 4.02 4.17
AMPS 12.0 12.3 12.7 13.2 13.0 13.3 13.8 14.3 14.2 14.5 15.0 15.6 15.1
15.5
16.0 16.7 16.1 16.5 17.1 17.8 17.1 17.5 18.1 18.8
HI PR 155 166 176 183 174 187 197 206 197 212 224 234 225
242
255 266 253 272 287 300 279 301 318 331
LO PR 61 65 71 76 65 69 75 80 67 72 78 83 71
75
82 87 74 79 86 92 77 82 89 95
* Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions
GSC130421B*