50
COOLING PERFORMANCE DATA
EXPANDED PERFORMANCE DATA COOLING OPERATION
MODEL: GSC130363B*/CA*F3636*6C*
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB*Airflow 59636771596367715963677159 63 67 715963677159636771
MBh 32.6 33.8 37.0 - 31.9 33.0 36.2 - 31.1 32.2 35.3 - 30.3 31.4 34.4 - 28.8 29.9 32.7 - 26.7 27.7 30.3 -
S/T 0.69 0.58 0.40 - 0.72 0.60 0.42 - 0.74 0.61 0.43 - 0.76 0.63 0.44 - 0.79 0.66 0.46 - 0.80 0.66 0.46 -
Delta T 19 16 12 - 19 17 13 - 19 17 13 - 19 17 13 - 19 16 12 - 18 15 12 -
1100 KW 2.34 2.38 2.45 - 2.49 2.54 2.61 - 2.62 2.67 2.75 - 2.74 2.79 2.87 - 2.84 2.89 2.98 - 2.93 2.98 3.07 -
AMPS 6.2 6.3 6.5 - 6.6 6.8 7.0 - 7.2 7.4 7.6 - 7.7 7.9 8.1 - 8.2 8.4 8.6 - 8.6 8.8 9.1 -
HI PR 135 145 153 - 151 163 172 - 172 185 195 - 196 211 222 - 220 237 250 - 243 262 276 -
LO PR 60 63 69 - 63 67 73 - 65 70 76 - 69 73 80 - 72 77 84 - 75 79 87 -
MBh 33.1 34.3 37.6 - 32.3 33.5 36.7 - 31.6 32.7 35.8 - 30.8 31.9 35.0 - 29.3 30.3 33.2 - 27.1 28.1 30.8 -
S/T 0.72 0.60 0.42 - 0.74 0.62 0.43 - 0.76 0.64 0.44 - 0.79 0.66 0.46 - 0.82 0.68 0.47 - 0.82 0.69 0.48 -
Delta T 18 16 12 - 18 16 12 - 18 16 12 - 19 16 12 - 18 16 12 - 17 15 11 -
70 1200 KW 2.37 2.41 2.47 - 2.52 2.57 2.64 - 2.66 2.70 2.78 - 2.77 2.83 2.91 - 2.87 2.93 3.01 - 2.96 3.02 3.11 -
AMPS 6.3 6.4 6.6 - 6.7 6.9 7.1 - 7.3 7.5 7.7 - 7.8 8.0 8.2 - 8.3 8.5 8.8 - 8.8 9.0 9.3 -
HI PR 137 147 156 - 154 165 175 - 175 188 199 - 199 214 226 - 224 241 254 - 247 266 281 -
LO PR 61 65 70 - 64 68 74 - 67 71 77 - 70 74 81 - 73 78 85 - 76 81 88 -
MBh 33.4 34.7 38.0 - 32.7 33.9 37.1 - 31.9 33.0 36.2 - 31.1 32.2 35.3 - 29.6 30.6 33.6 - 27.4 28.4 31.1 -
S/T 0.73 0.61 0.42 - 0.76 0.63 0.44 - 0.78 0.65 0.45 - 0.80 0.67 0.46 - 0.83 0.70 0.48 - 0.84 0.70 0.49 -
Delta T 17 15 11 - 18 15 12 - 18 15 12 - 18 15 12 - 17 15 11 - 16 14 11 -
1300 KW 2.37 2.42 2.48 - 2.53 2.57 2.64 - 2.66 2.71 2.79 - 2.78 2.83 2.91 - 2.88 2.94 3.02 - 2.97 3.03 3.11 -
AMPS 6.3 6.4 6.6 - 6.8 6.9 7.1 - 7.3 7.5 7.7 - 7.8 8.0 8.3 - 8.3 8.5 8.8 - 8.8 9.0 9.3 -
HI PR 137 148 156 - 154 166 175 - 175 189 199 - 200 215 227 - 225 242 255 - 248 267 282 -
LO PR 61 65 71 - 64 68 75 - 67 71 78 - 70 75 81 - 74 78 85 - 76 81 88 -
MBh 33.2 34.1 37.0 39.7 32.4 33.4 36.1 38.7 31.6 32.6 35.2 37.8 30.9
31.8
34.4 36.9 29.3 30.2 32.7 35.1 27.1 28.0 30.3 32.5
S/T 0.79 0.70 0.53 0.34 0.82 0.73 0.55 0.36 0.84 0.75 0.57 0.36 0.86
0.77
0.58 0.38 0.90 0.80 0.61 0.39 0.90 0.81 0.61 0.39
Delta T22201611222017122220171222
21
17 12 22 20 17 11 21 19 15 11
1100 KW 2.36 2.40 2.46 2.53 2.51 2.55 2.62 2.70 2.64 2.69 2.77 2.85 2.76
2.81
2.89 2.98 2.86 2.92 3.00 3.09 2.95 3.00 3.09 3.18
AMPS 6.2 6.4 6.6 6.8 6.7 6.9 7.1 7.3 7.3 7.4 7.7 8.0 7.8
7.9
8.2 8.5 8.2 8.4 8.7 9.0 8.7 8.9 9.2 9.6
HI PR 136 146 155 161 153 164 173 181 174 187 197 206 198
213
225 234 222 239 253 264 246 264 279 291
LO PR 60 64 70 74 64 68 74 79 66 70 77 82 69
74
81 86 73 77 85 90 75 80 87 93
MBh 33.7 34.7 37.5 40.3 32.9 33.9 36.6 39.3 32.1 33.1 35.8 38.4 31.3
32.2
34.9 37.5 29.8 30.6 33.2 35.6 27.6 28.4 30.7 33.0
S/T 0.82 0.73 0.55 0.36 0.85 0.76 0.57 0.37 0.87 0.78 0.59 0.38 0.90
0.80
0.61 0.39 0.93 0.83 0.63 0.40 0.94 0.84 0.63 0.41
Delta T21191611212016112120161121
20
16 11 21 20 16 11 20 18 15 10
75 1200 KW 2.38 2.43 2.49 2.56 2.54 2.59 2.66 2.73 2.67 2.72 2.80 2.88 2.79
2.85
2.93 3.01 2.90 2.95 3.04 3.13 2.98 3.04 3.13 3.22
AMPS 6.3 6.5 6.7 6.9 6.8 7.0 7.2 7.4 7.4 7.6 7.8 8.1 7.9
8.1
8.3 8.6 8.4 8.6 8.9 9.2 8.9 9.1 9.4 9.7
HI PR 138 149 157 164 155 167 176 184 177 190 201 209 201
216
228 238 226 243 257 268 250 269 284 296
LO PR 61 65 71 76 65 69 75 80 67 72 78 83 71
75
82 87 74 79 86 92 77 81 89 95
MBh 34.0 35.0 37.9 40.7 33.2 34.2 37.0 39.7 32.4 33.4 36.1 38.8 31.6
32.6
35.3 37.8 30.1 30.9 33.5 35.9 27.8 28.7 31.0 33.3
S/T 0.83 0.74 0.56 0.36 0.86 0.77 0.58 0.38 0.89 0.79 0.60 0.39 0.91
0.82
0.62 0.40 0.95 0.85 0.64 0.41 0.96 0.86 0.65 0.42
Delta T20181510201915112019151120
19
15 11 20 19 15 10 19 17 14 10
1300 KW 2.39 2.43 2.50 2.56 2.54 2.59 2.66 2.74 2.68 2.73 2.81 2.89 2.80
2.85
2.93 3.02 2.90 2.96 3.04 3.13 2.99 3.05 3.14 3.23
AMPS 6.3 6.5 6.7 6.9 6.8 7.0 7.2 7.5 7.4 7.6 7.8 8.1 7.9
8.1
8.3 8.7 8.4 8.6 8.9 9.2 8.9 9.1 9.4 9.7
HI PR 139 149 158 164 156 168 177 185 177 191 201 210 202
217
229 239 227 244 258 269 251 270 285 297
LO PR 61 65 71 76 65 69 75 80 67 72 78 83 71
75
82 88 74 79 86 92 77 82 89 95
* Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions
GSC130363B*