56
COOLING PERFORMANCE DATA
GSC130603A*
EXPANDED PERFORMANCE DATA COOLING OPERATION
MODEL: GSC130603A* / CA*F061*2* / CA*F4860*6**
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB*Airflow 59636771596367715963677159 63 67 715963677159636771
MBh 55.9 57.9 63.4 - 54.6 56.5 62.0 - 53.3 55.2 60.5 - 52.0 53.9 59.0 - 49.4 51.2 56.1 - 45.7 47.4 51.9 -
S/T 0.70 0.58 0.40 - 0.72 0.60 0.42 - 0.74 0.62 0.43 - 0.77 0.64 0.44 - 0.80 0.66 0.46 - 0.80 0.67 0.46 -
Delta T 19 16 12 - 19 16 12 - 19 16 12 - 19 17 13 - 19 16 12 - 18 15 12 -
1913 KW 3.97 4.06 4.19 - 4.29 4.38 4.53 - 4.57 4.67 4.83 - 4.81 4.92 5.09 - 5.02 5.14 5.31 - 5.20 5.32 5.50 -
AMPS 8.5 8.7 9.0 - 9.1 9.3 9.6 - 9.9 10.1 10.4 - 10.5 10.8 11.1 - 11.2 11.4 11.8 - 11.8 12.1 12.4 -
HI PR 144 155 163 - 161 174 183 - 183 197 208 - 209 225 237 - 235 253 267 - 260 279 295 -
LO PR 58 61 67 - 61 65 71 - 63 68 74 - 67 71 77 - 70 74 81 - 72 77 84 -
MBh 54.2 56.2 61.6 - 53.0 54.9 60.1 - 51.7 53.6 58.7 - 50.4 52.3 57.3 - 47.9 49.7 54.4 - 44.4 46.0 50.4 -
S/T 0.67 0.56 0.39 - 0.69 0.58 0.40 - 0.71 0.59 0.41 - 0.73 0.61 0.42 - 0.76 0.63 0.44 - 0.76 0.64 0.44 -
Delta T 20 17 13 - 20 17 13 - 20 17 13 - 20 17 13 - 20 17 13 - 18 16 12 -
70 1700 KW 3.94 4.03 4.16 - 4.25 4.35 4.49 - 4.53 4.63 4.78 - 4.77 4.88 5.04 - 4.98 5.09 5.26 - 5.16 5.28 5.45 -
AMPS 8.4 8.6 8.9 - 9.1 9.3 9.6 - 9.8 10.0 10.3 - 10.4 10.7 11.0 - 11.1 11.3 11.7 - 11.7 12.0 12.3 -
HI PR 142 153 162 - 160 172 181 - 182 195 206 - 207 223 235 - 233 250 264 - 257 277 292 -
LO PR 57 61 66 - 60 64 70 - 63 67 73 - 66 70 77 - 69 74 80 - 72 76 83 -
MBh 50.1 51.9 56.8 - 48.9 50.7 55.5 - 47.7 49.5 54.2 - 46.6 48.3 52.9 - 44.2 45.8 50.2 - 41.0 42.5 46.5 -
S/T 0.64 0.54 0.37 - 0.67 0.56 0.39 - 0.68 0.57 0.40 - 0.70 0.59 0.41 - 0.73 0.61 0.42 - 0.74 0.62 0.43 -
Delta T 20 17 13 - 20 17 13 - 20 17 13 - 20 18 13 - 20 17 13 - 19 16 12 -
1488 KW 3.84 3.93 4.05 - 4.15 4.24 4.38 - 4.41 4.51 4.66 - 4.65 4.76 4.91 - 4.85 4.96 5.13 - 5.02 5.14 5.31 -
AMPS 8.2 8.4 8.7 - 8.8 9.0 9.3 - 9.5 9.8 10.1 - 10.2 10.4 10.7 - 10.8 11.0 11.4 - 11.4 11.6 12.0 -
HI PR 138 149 157 - 155 167 176 - 176 190 200 - 201 216 228 - 226 243 256 - 249 268 283 -
LO PR 56 59 64 - 59 62 68 - 61 65 71 - 64 68 74 - 67 71 78 - 69 74 81 -
MBh 56.8 58.5 63.3 67.9 55.5 57.1 61.8 66.4 54.2 55.8 60.4 64.8 52.8
54.4
58.9 63.2 50.2 51.7 55.9 60.0 46.5 47.9 51.8 55.6
S/T 0.79 0.71 0.54 0.35 0.82 0.74 0.56 0.36 0.84 0.75 0.57 0.37 0.87
0.78
0.59 0.38 0.90 0.81 0.61 0.39 0.91 0.82 0.62 0.40
Delta T22201611222017112220171122
20
17 12 22 20 16 11 20 19 15 11
1913 KW 4.01 4.09 4.23 4.37 4.33 4.42 4.57 4.72 4.61 4.71 4.87 5.03 4.85
4.96
5.13 5.31 5.06 5.18 5.36 5.54 5.25 5.37 5.55 5.74
AMPS 8.6 8.8 9.0 9.3 9.2 9.4 9.7 10.1 10.0 10.2 10.5 10.9 10.6
10.9
11.2 11.6 11.3 11.5 11.9 12.3 11.9 12.2 12.6 13.0
HI PR 145 156 165 172 163 175 185 193 185 199 211 220 211
227
240 250 237 255 270 281 262 282 298 311
LO PR 58 62 68 72 62 66 72 76 64 68 74 79 67
72
78 83 71 75 82 87 73 78 85 90
MBh 55.1 56.8 61.5 66.0 53.9 55.5 60.0 64.4 52.6 54.1 58.6 62.9 51.3
52.8
57.2 61.4 48.7 50.2 54.3 58.3 45.1 46.5 50.3 54.0
S/T 0.76 0.68 0.51 0.33 0.78 0.70 0.53 0.34 0.80 0.72 0.54 0.35 0.83
0.74
0.56 0.36 0.86 0.77 0.58 0.38 0.87 0.78 0.59 0.38
Delta T23211712232117122321171223
21
17 12 23 21 17 12 21 20 16 11
75 1700 KW 3.97 4.06 4.19 4.33 4.29 4.38 4.53 4.68 4.57 4.67 4.83 4.99 4.81
4.92
5.09 5.26 5.02 5.14 5.31 5.49 5.20 5.32 5.50 5.69
AMPS 8.5 8.7 9.0 9.3 9.1 9.3 9.6 10.0 9.9 10.1 10.4 10.8 10.5
10.8
11.1 11.5 11.2 11.4 11.8 12.2 11.8 12.1 12.5 12.9
HI PR 144 155 163 170 161 174 183 191 183 197 208 217 209
225
237 248 235 253 267 279 260 279 295 308
LO PR 58 62 67 72 61 65 71 76 63 68 74 79 67
71
77 82 70 74 81 86 72 77 84 89
MBh 50.9 52.4 56.7 60.9 49.7 51.2 55.4 59.5 48.5 50.0 54.1 58.1 47.3
48.8
52.8 56.6 45.0 46.3 50.1 53.8 41.7 42.9 46.4 49.8
S/T 0.73 0.65 0.49 0.32 0.76 0.68 0.51 0.33 0.78 0.69 0.53 0.34 0.80
0.72
0.54 0.35 0.83 0.74 0.56 0.36 0.84 0.75 0.57 0.37
Delta T23211712232118122321181223
22
18 12 23 21 17 12 22 20 16 11
1488 KW 3.88 3.96 4.09 4.22 4.18 4.27 4.42 4.56 4.45 4.55 4.70 4.86 4.69
4.80
4.96 5.13 4.89 5.00 5.17 5.35 5.07 5.18 5.36 5.55
AMPS 8.3 8.5 8.7 9.0 8.9 9.1 9.4 9.7 9.6 9.8 10.2 10.5 10.2
10.5
10.8 11.2 10.9 11.1 11.5 11.9 11.5 11.7 12.1 12.6
HI PR 139 150 158 165 156 168 178 185 178 191 202 211 203
218
230 240 228 245 259 270 252 271 286 299
LO PR 56 60 65 69 59 63 69 73 62 66 72 76 65
69
75 80 68 72 79 84 70 75 81 87
* Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions