EasyManuals Logo

Goodwe DNS Series User Manual

Goodwe DNS Series
47 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #4 background imageLoading...
Page #4 background image
III
CONTENT
User Manual V1.0-2022-12-15
6.1 Safety Precaution .......................................................................................15
6.2 Connecting the PE Cable ...........................................................................16
6.3 Connecting the PV Input Cable ................................................................16
6.4 Connecting the AC Output Cable .............................................................18
6.5 Communication ..........................................................................................22
6.5.1 Communication Network Introduction ............................................................22
6.5.2 Connecting the Communication Cable (optional) ........................................... 23
6.5.3 Installing the Communication Module (optional) ...........................................25
7 Equipment Commissioning .................................................26
7.1 Check Before Power ON ............................................................................26
7.2 Power On .....................................................................................................26
8 System Commissioning .......................................................27
8.1 Indicators and Buttons ..............................................................................27
8.2 Setting Inverter Parameters via LCD .......................................................27
8.2.1 Inverter Parameter Introduction ......................................................................30
8.3 Upgrading the Firmware Via USB Flash Disk ..........................................31
8.4 Setting Inverter Parameters via SolarGo App ........................................31
8.5 Monitoring via SEMS Portal .....................................................................32
9 Maintenance .........................................................................33
9.1 Power O the Inverter ...............................................................................33
9.2 Removing the Inverter ...............................................................................33
9.3 Disposing of the Inverter ..........................................................................33
9.4 Troubleshooting .........................................................................................33
9.5 Routine Maintenance .................................................................................35
10 Technical Parameters ........................................................36

Other manuals for Goodwe DNS Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Goodwe DNS Series and is the answer not in the manual?

Goodwe DNS Series Specifications

General IconGeneral
Max. Efficiency97.8%
MPPT Efficiency99.9%
Cooling MethodNatural Convection
Protection RatingIP65
Start Voltage80 V
Nominal AC Voltage230 V
THDi<3%
Number of MPPTs2
Output Voltage230 V
Frequency50 Hz / 60 Hz
TypeGrid-Tied Inverter
Rated Power Output3000W, 3600W, 4200W, 5000W
CommunicationRS485
Max. DC Input Power4500W, 5400W, 6300W, 7500W
Max. DC Voltage550V
MPPT Voltage Range80-500V
Rated AC Output Power3000W, 3600W, 4200W, 5000W
AC Voltage Range180V - 280V
Power Factor0.8 leading to 0.8 lagging
Operating Temperature Range-25°C to 60°C
MPPT Range80-500V
ModelDNS Series

Related product manuals