EasyManuals Logo

Goodwe DNS Series User Manual

Goodwe DNS Series
47 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #6 background imageLoading...
Page #6 background image
01 Disclaimer
2
User Manual V1.0-2022-12-15
1.3 Symbol Denition
1.4 Updates
The latest document contains all the updates made in earlier issues.
V1.0 2022-12-15
First Issue
Dierent levels of warning messages in this manual are dened as follows:
DANGER
Indicates a high-level hazard that, if not avoided, will result in death or serious injury.
WARNING
Indicates a medium-level hazard that, if not avoided, could result in death or serious injury.
CAUTION
Indicates a low-level hazard that, if not avoided, could result in minor or moderate injury.
NOTICE
Highlight and supplement the texts. Or some skills and methods to solve product-related
problems to save time.

Other manuals for Goodwe DNS Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Goodwe DNS Series and is the answer not in the manual?

Goodwe DNS Series Specifications

General IconGeneral
Max. Efficiency97.8%
MPPT Efficiency99.9%
Cooling MethodNatural Convection
Protection RatingIP65
Start Voltage80 V
Nominal AC Voltage230 V
THDi<3%
Number of MPPTs2
Output Voltage230 V
Frequency50 Hz / 60 Hz
TypeGrid-Tied Inverter
Rated Power Output3000W, 3600W, 4200W, 5000W
CommunicationRS485
Max. DC Input Power4500W, 5400W, 6300W, 7500W
Max. DC Voltage550V
MPPT Voltage Range80-500V
Rated AC Output Power3000W, 3600W, 4200W, 5000W
AC Voltage Range180V - 280V
Power Factor0.8 leading to 0.8 lagging
Operating Temperature Range-25°C to 60°C
MPPT Range80-500V
ModelDNS Series