02 INSTALLATION INSTRUCTIONS
2.1 Select Mounting Location
For inverter's protection and convenient maintenance, mounting location for inverter should be
selected carefully based on the following rules:
Any part of this system shouldn't block the switch and breaker from disconnecting the inverter from
DC and AC power.
Rule 1. Inverter should be installed on a solid surface, where is suitable for inverter's dimensions
and weight.
Rule 2. Inverter should be installed horizontally.
Rule 3. Ambient temperature should be lower than 45°C. (High ambient temperature will cause
power derating of inverter.)
Rule 4. The inverter should be installed indoors.
Rule 5. Bearing capacity of the 󽗊oor must be higher than 300kg/m
2
.
Rule 6. Inverter should be installed at eye level for convenient maintenance.
Rule 7. Product label on inverter should be clearly visible after installation.
Rule 8. Leave enough space around the inverter according to the below 󽗉gure.
Rule 9. Suitable for mounting on concrete or other non-combustible surfaces only
Dimensions
1350mm
585mm
750mm