FollowthePressureReliefProcedure
wheneveryouseethissymbol.
Thisequipmentstayspressurizeduntilpressure
isrelievedmanually.Tohelppreventserious
injuryfrompressurizeduid,suchassplashing
intheeyesoronskin,followthePressureRelief
Procedurewhenyoustoppumpingandbeforeyou
clean,check,orservicetheequipment.
1.Shutofftheairsupplytothepump.
2.Openthedispensingvalve,ifused.
3.Opentheuiddrainvalvetorelieveuid
pressure.Haveacontainerreadytocatchthe
drainage.
Replace Replace
Replace
Complete Complete
Complete
Air Air
Air
Valve Valve
Valve
FollowtheseinstructionstoinstallAirValve
ReplacementKit24V231.
1.Stopthepump.Followthe
PressureReliefProcedure,page10.
2.Disconnecttheairlinetothemotor.
3.Removenuts(104).Removetheairvalve(102)
andgasket(105).
4.Alignthenewairvalvegasket(105*)onthe
centerhousing,thenattachthenewairvalve.
FollowtheTorqueInstructions,page18.
5.Reconnecttheairlinetothemotor.
103A2714H