FollowthePressureReliefProcedure
wheneveryouseethissymbol.
Thisequipmentstayspressurizeduntilpressure
isrelievedmanually.Tohelppreventserious
injuryfrompressurized󰘱uid,suchassplashing
intheeyesoronskin,followthePressureRelief
Procedurewhenyoustoppumpingandbeforeyou
clean,check,orservicetheequipment.
1.Shutofftheairsupplytothepump.
2.Openthedispensingvalve,ifused.
3.Openthe󰘱uiddrainvalvetorelieve󰘱uid
pressure.Haveacontainerreadytocatchthe
drainage.
Replace Replace
Replace
Complete Complete
Complete
Air Air
Air
Valve Valve
Valve
FollowtheseinstructionstoinstallAirValve
ReplacementKit24V231.
1.Stopthepump.Followthe
PressureReliefProcedure,page10.
2.Disconnecttheairlinetothemotor.
3.Removenuts(104).Removetheairvalve(102)
andgasket(105).
4.Alignthenewairvalvegasket(105*)onthe
centerhousing,thenattachthenewairvalve.
FollowtheTorqueInstructions,page18.
5.Reconnecttheairlinetothemotor.
103A2714H