26 308573
Performance Charts
Air Consumption
To find Pump Air Consumption (scfm or m#/min) at a specific
fluid flow (gpm/lpm) and air pressure (psi/MPa/bar):
1. Locate fluid flow rate along bottom of chart.
2. Read vertical line up to intersection with selected air
consumption curve.
3. Follow left to scale to read air consumption.
0
5
10
15
20
25
30
0246810121416
A
B
C
A
B
C
Test Conditions: Pump tested in water with fluid inlet submerged
and air inlet restrictor removed. For performance with air inlet
restrictor in place, see manual 308589.
AIR CONSUMPTION – scfm (cubic meters/min)
(0.84)
(0.70)
(0.56)
(0.42)
(0.28)
(7.6)
(15.2) (22.7)
(30.3)
(37.9)
(45.4)
(53.0)
(60.6)
Air Consumption Curves
at 100 psi (0.7 MPa, 7 bar) air pressure
at 70 psi (0.48 MPa, 4.8 bar) air pressure
at 40 psi (0.28 MPa, 2.8 bar) air pressure
(0.14)
FLUID FLOW – gpm (lpm)