308573 25
Performance Charts
To find Fluid Outlet Pressure (psi/MPa/bar) at a specific fluid
flow (gpm/lpm) and operating air pressure (psi/MPa/bar):
1. Locate fluid flow rate along bottom of chart.
2. Follow vertical line up to intersection with selected fluid
outlet pressure curve.
3. Follow left to scale to read fluid outlet pressure.
0
20
40
60
80
100
0246810121416
A
B
C
A
B
C
Test Conditions: Pump tested in water with fluid inlet submerged
and air inlet restrictor removed. For performance with air inlet
restrictor in place, see manual 308589.
FLUID OUTLET PRESSURE – psi (MPa, bar)
(0.7, 7)
(0.55, 5.5)
(0.41, 4.1)
(0.28, 2.8)
(0.14, 1.4)
Fluid Pressure Curves
at 100 psi (0.7 MPa, 7 bar) air pressure
at 70 psi (0.48 MPa, 4.8 bar) air pressure
at 40 psi (0.28 MPa, 2.8 bar) air pressure
Fluid Outlet Pressure
(7.6)
(15.2)
(22.7)
(30.3)
(37.9)
(45.4)
(53.0)
(60.6)
FLUID FLOW – gpm (lpm)