Accessories
3A2347ZAA 109
Overtemperature Jumper,
16Y727
Use the Overtemperature jumper plug to run the
InvisiPac melter without a hose and gun attached to the
Channel 1 electrical connection.
Installation
1. In the ADM setup screens, uninstall Channel 1. All
other Channels can be installed or uninstalled as
needed.
NOTE: Failure to uninstall Channel 1 on the ADM setup
screens will result in several Alarms regarding Channel
1 when there is no hose/gun attached to Channel 1.
2. Attach the Overtemperature jumper plug to Channel
1.
3. The ADM should have zero Active Alarms. The
melter is now ready to run without a hose and gun
attached to Channel 1.
Strain Relief Bushing Kit,
24X190
The strain relief bushing kit allows the use of a smaller
outside diameter (OD) power cord. This strain relief
bushing is intended for power cords with an OD of
0.512-1.024 in (13-26 mm).
Installation
1. Remove standard strain relief bushing (106). Retain
and reuse nut.
2. Install strain relief bushing from kit and secure with
retained nut.