Setup
18 3A2347ZAA
Connect Electrical Cord
NOTE: See Grounding section on page 13.
NOTE: The installed strain relief bushing (106) fits a
0.708-1.260 in. OD electrical cord. See FIG.14.If
needed, use a wrench to tighten the strain relief bushing
until it is snug on the cable.
NOTE: Tubing 17F777 and 17F779 is included for
smaller diameter electrical cord. Place around the power
cord and secure in the strain relief brushing (106).
NOTE: The accessory strain relief bushing kit 24x190 is
available for smaller (0.512-1.024 in, 13-26 mm) OD
electrical cords. See Accessories, page 107.
For 480V Electrical Circuits, see page 20.
1. Turn main power switch OFF.
2. Disconnect cable from ADM, push cable through
plastic shroud, then remove plastic shroud from sys-
tem.
3. Remove electrical enclosure access door (T). See
FIG. 2 on page 9.
4. Ensure the terminal block jumpers are in the correct
locations for the phase and voltage used. If neces-
sary, change them to match FIG. 15 on page 19.
See the following table, FIG. 13, and FIG.15.
NOTE: The jumpers only need to be changed if using a
different phase or voltage from what the system was
designed for at the factory.
NOTE: All necessary jumpers are supplied with the sys-
tem in a bag located behind the electrical enclosure
front access panel. Keep unused jumpers in bag.
NOTE: Use the supplied hard metal 2, 3, and 5 terminal
jumpers and jumper wire for terminals 2C-10C. Use the
red, plastic jumpers for terminals 11-14.
5. Insert electrical cord through electrical enclosure
strain relief bushing (106). See FIG. 14 on page 19.
a. Alternate electrical cord routing: using conduit,
run electrical cord from access port (X) through
hole (Y). Conduit is required when routing wires
near compressed air components.
Improper wiring may cause electric shock or other
serious injury if work is not performed properly. Have
a qualified electrician perform any electrical work. Be
sure your installation complies with all National, State
and Local safety and fire codes.
To reduce the risk of electric shock, perform the
entire Attach Components procedure beginning on
page 13 prior to connecting electrical cord.
NOTICE
To prevent system damage, verify terminal jumpers are
installed correctly before going on to the next step.
Terminal Block Jumper Installation Guide
Voltage
Terminal Block Location
Jumper
Wire
127201
2-Terminal
Jumper
126814
3-Terminal
Jumper
126815
5-Terminal
Jumper
126816
200-240VAC,
1 phase
Not used Not used 3-5 6-10
350-415VAC,
3 phase,
WYE
Not used
5-6,
8-9
2-4 Not used
200-240VAC,
3 phase,
DELTA
3-7
4-5,
9-10
6-8 Not used
FIG. 13: Jumpers
ti21182a
2-Terminal
3-Terminal
5-Terminal
Wire
126814
126815
126816
127201