Setup
3A2347ZAA 19
6. Attach insulated ferrules to the end of each wire. 7. Connect ground wire to chassis ground (AF). See
FIG.14.
8. Connect L1, L2, L3, and N as shown in FIG. 15. Not
all models use all 4 wires.
9. Use zip ties to secure the electrical cord to the
tie-downs located on the top of the inside of the
electrical enclosure.
10. Tighten screw-terminals to at least 10 in-lb
(1.1 N•m).
11. Install electrical enclosure door.
12. Perform Select ADM Settings on page 20 prior to
turning on heat.