Technical Data
120 3A2347ZAA
Technical Data
InvisiPac Hot Melt Delivery System
US Metric
Electrical
Electrical Service 24P260: 200-240VAC, 1-ph, 50/60 Hz, 32A Max
24P261: 200-240VAC, 1-ph, 50/60 Hz, 40A Max
24P262: 350-415VAC/200-240VAC, 3-ph with Neutral, 50/60 Hz, 16A
Max
24P263: 350-415VAC/200-240VAC, 3-ph with Neutral, 50/60 Hz, 16A
Max
24P264: 200-240VAC, 3-ph without Neutral, 50/60 Hz, 27A Max
24P265: 200-240VAC, 3-ph without Neutral, 50/60 Hz, 27A Max
24U132: 200-240VAC, 1-ph, 50/60 Hz, 40A Max
24U133: 350-415VAC/200-240VAC, 3-ph with Neutral, 50/60 Hz, 30A
Max
24U134: 200-240VAC, 3-ph without Neutral, 50/60 Hz, 40A Max
Maximum Gun Wattage Per Channel 400 W
Input / Output Capability 4 inputs (0-30VDC), 4 outputs (240VAC, 24VDC, 2A)
General
Adhesive 1/4 in. (6 mm), round, adhesive pellets
Pump Flow Rate 96 lb/hr 43.5 kg/hr
Pump Output 6.2 cc/cycle
Time to Temperature * Less than 10 minutes
Melt Rate / Constant Throughput 25 lb/hr 11.3 kg/hr
Pump Pneumatic Piston, 12:1
Channels 1 to 4
System Dimensions, without vacuum tube or
shaker (Width x Height x Depth) **
19.0 x 42 x 16.5 in. 483 x 1067 x 419 mm
Shaker Dimensions (Width x Height) 0.4 x 4.0 ft 0.12 x 1.22 m
Weight 85 lb 39 kg
Pressure and Temperature Ranges
Main System Air Supply Pressure Range (set with
regulator on front of system)
80-100 psi 0.55-0.69 MPa (5.5-7 bar)
Pump Operating Air Pressure Range 20-100 psi 0.14-0.69 MPa (0.7-7 bar)
Pump Operating Fluid Pressure Range 240-1200 psi 1.7-8 MPa (17-80 bar)
Control Temperature Range 100-400°F 38-204°C
Ambient Temperature Range 32-120°F 0-49°C
Vacuum Transfer Specifications
Maximum Vacuum Transfer Hose Length 30 ft 9.1 m
Maximum Vacuum Transfer Hose Maximum Verti-
cal Rise
10 ft 3.0 m
Vacuum Transfer Operating Pneumatic Pressure
Range (set with regulator on front of system)
40-100 psi 280-690 kPa (2.8-6.9 bar)
Vacuum Transfer Air Consumption at 40 psi (280
kPa, 2.8 bar),
9.5 scfm (intermittent duty; 4% at
25 lb/hr)
16.1 scmh (intermittent duty; 4% at
11.3 kg/hr)
Vacuum Transfer Air Consumption at 80 psi (550
kPa, 5.5 bar)
17.2 scfm (intermittent duty; 4% at
25 lb/hr)
29.2 scmh (intermittent duty; 4% at
11.3 kg/hr)