Troubleshooting
40 3A2347ZAA
Troubleshooting
ADM Error Code Table
When an error occurs, press to acknowledge the error. If a Maintenance error occurs, navigate to the Mainte-
nance screen and press to clear the error.
The last digit of the error code indicates the melter, gun, or hose to which the error applies. The ā€œ_ā€ (underscore)
character indicates the code applies to multiple items.
An alarm will disable the heating system and pump. A deviation or advisory with not disable the heating system and
pump.
To avoid injury due to unexpected machine operation
initiated by a remote controller, disconnect the
customer I/O cable from the system prior to
troubleshooting.
Last Digit in Code Code Relates to:
0 Melter
1 Gun 1
2 Hose 1
3 Gun 2
4 Hose 2
5 Gun 3
6 Hose 3
7 Gun 4
8 Hose 4
9 Gun 5
A Hose 5
B Gun 6
C Hose 6
Code Description Type Cause Solution
A4D0 High Current
Melter
Alarm Band heater or rod heater. Measure resistance to ground between
heater leads. Replace band heater or rod
heater. See Replace Band Heater (page 60),
or Replace Rod Heater (page 62).
A4D_ High Current
Hose X
Alarm Hose power wires. Check heater resistance and resistance to
ground. Replace heated hose.
A4D_ High Current
Gun X
Alarm Heater rods in gun manifold. Check heater resistance and resistance to
ground. Replace gun manifold.