Component Identification
12 3A2347ZAA
Screen Components
FIG. 6: Main Screen Components
Operating Mode Description Component Status
System Off
The system doesn’t have power.
• No System Status Indicator LED on the
ADM
• No heat
• Pump is off
Inactive
The heating system and pumps are
disabled.
• Yellow system status indicator LED on the
ADM
• No heat
• Pump is off (manually changed)
Warm Up
The system is increasing the material
to the set temperature.
• Flashing green system status indicator LED
on the ADM
• Heat is increasing to setpoint temperature
• Pump is off
Active
The system is ready to dispense
material.
• Solid green system status indicator LED on
the ADM
• Heat is at setpoint temperature
• Pump is on