Setup/Startup
14 3A4603C Operation, Repair, Parts
Setup/Startup
1. Perform
Pressure Relief Procedure
, page 13
.
2. Charge Battery, page 10.
3. Perform Grounding Procedure (AC Wall Power),
page 11, or Grounding Procedure (Battery
Power), page 12, if using flammable materials.
4. Fill throat packing nut with TSL to prevent
premature packing wear. Do this daily or each time
you spray.
a. Place the TSL bottle nozzle into the top center
opening in the grill at the front of the sprayer.
b. Squeeze bottle to dispense enough TSL to fill
the space between the pump rod and packing
nut seal.
NOTE: If running off wall power, plug cord into charging
port. If using an extension cord, use a 3-wire, 12 AWG
(2.5mm
2
) minimum with an undamaged ground contact.
5. Turn On/OFF Switch to OFF.
6. If removed, install strainer.
7. Turn prime valve down. Turn pressure control coun-
terclockwise to lowest pressure.
NOTE: Minimum hose size for proper sprayer opera-
tion is 1/4 in. x 50 ft for LL ES 1000.
8. Place siphon tube set in grounded metal pail par-
tially filled with flushing fluid. Attach ground wire to
true earth ground. Use water to flush water-based
paint and mineral spirits to flush oil-based paint and
storage oil.