Cleanup
22 3A4603C Operation, Repair, Parts
Cleanup
1. Perform Pressure Relief Procedure, page 13.
2. Remove guard and SwitchTip from all guns.
3. Unscrew cap, remove filter. Assemble without filter.
4. Clean filter, guard and SwitchTip in flushing fluid.
5. Attach ground wire to true earth ground or plug unit
into grounded outlet.
Fast Flush Drain Tube
6. Remove fluid intake and drain tube from paint, wipe
excess paint off outside.
7. Place siphon tube set in grounded metal pail
partially filled with flushing fluid. Use water for water
base paint and mineral spirits for oil-based paint.
8. To flush drain tube and pump turn prime valve down.
9. Turn pressure control to Fast Flush operate until the
pump runs steady and flushing fluid appears in the
waste pail.