Setup/Startup
3A4603C Operation, Repair, Parts 15
9. Turn ON/OFF Switch to ON:
10. Turn pressure control to prime. Allow fluid to circu-
late for 15 seconds.
11. Turn pressure down, turn prime valve horizontal.
Disengage gun trigger lock.
12. Hold all guns against a grounded metal flushing pail.
Trigger guns and increase fluid pressure slowly until
pump runs smoothly. Turn up as needed to
prime/spray.
13. Inspect fittings for leaks. If leaks occur, turn sprayer
OFF immediately. Perform
Pressure Relief Proce-
dure
, page 13. Tighten leaky fittings. Repeat
Setup/Startup
, steps 1 - 17. If no leaks, continue to
trigger gun until system is thoroughly flushed. Pro-
ceed to step 18.
14. Place siphon tube in paint pails.
15. Trigger all guns again into a flushing fluid pail until
paint appears. Assemble tips and guards.
SwitchTip and Guard Assembly
1. Engage trigger lock. Use end of SwitchTip to press
OneSeal into tip guard, with curve matching tip bore.
2. Insert SwitchTip in tip bore and firmly thread assem-
bly onto gun.
High-pressure spray is able to inject toxins into the
body and cause serious bodily injury. Do not stop
leaks with hand or rag.
To avoid serious injury from skin injection do not put
your hand in front of the spray tip when installing or
removing the spray tip and tip guard.
ti27613a
ti27774a