Cleanup
3A4603C Operation, Repair, Parts 23
Fast Flush Hose and Gun
10. To flush airless hose and spray gun, turn prime
valve horizontal.
11. Hold gun against waste pail. Disengage trigger lock.
Trigger gun and turn pressure control to Fast Flush
operate until the pump runs steady and flushing fluid
appears.
12. Stop triggering gun.
13. Fill pump with Pump Armor and reassemble filter,
guard and SwitchTip.
14. Each time you spray and store, fill throat packing
nut with TSL to decrease packing wear.