Hydraulic Gun Manifold Replacement
3A3394E Repair - Parts 21
4. Observe label on bracket. Push labeled gun cables
into manifold brackets.
5. Connect gun cables to actuators.
6. Connect three wire harnesses to solenoids.
7. Install pad and tighten four screws.
8. Install front shield to unit and tighten six screws.
9. Install tank(s), lid(s) and insert siphon tube(s) into
tank(s).
NOTE: The hydraulic gun manifold is self-purging.
ti23964a
ti23916a
Gun 2
Gun 3
Gun 1