Setup
3A4702E 11
Setup
Pressure Relief Procedure
1.
Turn Prime Knob down to PRIME position
to relieve pressure
.
Sprayer Setup
1. Insert one FlexLiner into the Cup
Support.
NOTE: Verify there is no damage to the top
sealing edge of the FlexLiner, such as a
crease or fold. If damaged it will leak air and
lose prime.
This sprayer builds up an internal
pressure of 2000 psi (138 bar, 13.8 MPa)
during use. Follow this Pressure Relief
Procedure whenever you stop spraying
and before cleaning, checking, servicing,
or transporting equipment to prevent
serious injury from pressurized fluid.
Use only water-based materials. Do not
use materials which state “FLAMMABLE”
on the packaging. For more information
about your material, request a Safety Data
Sheet (SDS) from distributor or retailer.
Keep spray area well-ventilated. Keep a
good supply of fresh air moving through
the area.