EasyManua.ls Logo

Graco Reactor 2 H-30 - Repair Heated Hose

Graco Reactor 2 H-30
110 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Repair
Repair Repair
Repair
Heated Heated
Heated
Hose Hose
Hose
Refertotheheatedhosemanual309572forhose
replacementparts.
Check Check
Check
Hose Hose
Hose
Wires Wires
Wires
1.PerformShutdown,page48.
NOTE: NOTE:
NOTE:
Whiphosemustbeconnected.
2.Removecover(CV).
3.DisconnectsystemwiresfromtheReactor.
4.Disconnecthosewires(HW)fromterminalblock
(TB),seeFig3.
5.Usinganohmmeter,checkbetweenthehose
wires(HW).Thereshouldbecontinuity.
6.Ifhosefailstest,retestateachlengthofhose
fromthesystemouttothegun,includingwhip
hose,untilfailureisisolated.
7.Reconnectwiresandinstallcover(CV).
Check Check
Check
RTD RTD
RTD
Cables Cables
Cables
and and
and
FTS FTS
FTS
1.PerformShutdown,page48.
2.DisconnectRTDcable(C)atReactor(SC).
3.TestwithanohmmeterbetweenpinsofM8cable
connectorC.
NOTE: NOTE:
NOTE:
Donottouchouterringwithtestprobe
whilemeasuringresistance.
M8 M8
M8
Connector Connector
Connector
Pins Pins
Pins
Resistance Resistance
Resistance
3to1
SeeRTDResistance
vs.Temperature,
page63.
3to4
SeeRTDResistance
vs.Temperature,
page63.
1to40.2-0.4ohmsatthe
FTS(each50ftcable
adds2.5ohms)
2toany
in󰘰nity(open)
4.Retestateachlengthofhose,includingwhip
hose,untilfailureislocated.
5.IftheFTSisnotreadingproperlyattheendof
thehose,connectFTSdirectlytoRTDcable(C)
atthemanifold.
6.IftheFTSreadsproperlyatthemanifoldbut
notattheendofthehose,checkcable(C)
connections.Verifytheyaretight.
HeatedHose
Figure8
NOTE: NOTE:
NOTE:
Toassistintakingreadings,orderRTD
TestKit24N365.Kitincludestwocables:one
cablewithacompatiblefemaleM8connector
andanothercablewithamaleM8connector.
Bothcableshavestrippedwireattheotherend
foreasytestprobeaccess.
Pins Pins
Pins
/ /
/
Wire Wire
Wire
Color Color
Color
Result Result
Result
3to1/browntoblue
SeeRTDResistance
vs.Temperature,
page63.
3to4/bluetoblack
SeeRTDResistance
vs.Temperature,
page63.
1to4/browntoblack0.2-0.4ohmsatthe
FTS(each50ftcable
adds2.5ohms)
2toany/N/A
in󰘰nity(open)
62 334946H

Table of Contents

Other manuals for Graco Reactor 2 H-30