Startup
11.PresstoactivateADM.
12.Ifnecessary,setuptheADMinSetupMode.See
AdvancedDisplayModule(ADM)Operation,
page34.
13.Preheatthesystem:
a.Press
toturnonhoseheatzone.
NOTE: NOTE:
NOTE:
Inordertorunwithouta󰘱uid
temperaturesensorinHoseResistance
Mode,acalibrationfactormustbesaved.
SeeCalibrationProcedure,page57.
Thisequipmentisusedwithheated󰘱uid
whichcancauseequipmentsurfaces
tobecomeveryhot.Toavoidsevere
burns:
Donottouchhot󰘱uidorequipment.
Donotturnonhoseheatwithout󰘱uid
inhoses.
Allowequipmenttocoolcompletely
beforetouchingit.
Wearglovesif󰘱uidtemperature
exceeds110°F(43°C).
Thermalexpansioncancause
over-pressurization,resultingin
equipmentruptureandseriousinjury,
including󰘱uidinjection.Donot
pressurizesystemwhenpreheating
hose.
b.Ifyouneedtocirculate󰘱uidthroughthe
systemtopreheatthedrumsupply,see
CirculationThroughReactor,page50.
Ifyouneedtocirculatematerialthrough
theheathosetothegunmanifold,see
CirculationThroughGunManifold,page51.
c.Waitforthehosetoreachsetpoint
temperature.
NOTE: NOTE:
NOTE:
Hoseheat-uptimemayincreaseat
voltageslessthannominal230VACwhen
maximumhoselengthisused.
d.Press
toturnonAandBheatzones.
334945J 49