Warnings
WARNING
THERMAL EXPANSION HAZARD
Fluidssubjectedtoheatinconnedspaces,includinghoses,cancreatearapidriseinpressure
due to the thermal expansion. Over-pressurization can res ult in equipment rupture and serious
injury.
Openavalvetorelievethefluidexpansionduringheating.
Replace hoses proactively at regular intervals based on your operating conditions.
PRESSURIZED ALUMINUM PARTS HAZARD
Use of uids that are incompatible with aluminum in pressurized equipment can cause serious
chemical reaction and equipment rupture. Failure to follow this warning can result in death,
serious injury, or property damage.
Do not use 1,1,1-trichloroethane, methylene chloride, other h alogenated hydrocarbon
solvents or uids containing such s olvents.
Many other fluids may co ntain chemicals that can react with aluminum. Contact your material
supplier for compatibility.
PLASTIC
PARTS CLEANING SOLVENT HAZARD
Many solvents can degrade plastic parts and cause them to fail, which could cause serious
injury or property damage.
Use only compatible wate r-based solvents to clean plastic structural or pressure-containing
parts.
•See
Technical Data
in this and all other equipment instruction manuals. Read uid a nd
solvent manufacturer’s MSDSs and recommendations.
332636D 5

Other manuals for Graco Reactor 2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Graco Reactor 2 and is the answer not in the manual?

Graco Reactor 2 Specifications

General IconGeneral
BrandGraco
ModelReactor 2
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals