Spraying
10. Open gun uid inlet valves A and B.
Fusion Probler
NOTICE
To prevent c rossover on impingement gun s,
never
open uid manifold valv es or trigger gun
if pressures are imbalanced.
11. Disengage gun piston safety lock.
Fusion Probler
12. Pull gun trigger to test spray onto cardboard. If
necessary, adjust pressure and temperature to
get desired results.
Spray Adjustments
Flow rate, atomization, and amount of overspray are
affected by four va riables.
Fluid pressure setting.
Toolittlepressureresults
in an uneven pattern, coarse droplet size, low
ow, and poor mixing. Too much pressure results
in excessive overspray, high flow rates, difcult
control, and excessive wear.
Fluid temperature.
Similar effects to fluid pressure
setting. The A and B temperatures can be offset to
help balance the fluid pressure.
Mix chamber size.
Choice of mix chamber is based
on desired ow rate and uid viscosity.
Clean-off air adjustment.
Too littl e clean-off air
resultsindropletsbuildinguponthefrontofthe
nozzle, and no pattern containment to control
overspray. Too much clean-off air results in
air-assisted atomization and excessive overspray.
64 332636D

Other manuals for Graco Reactor 2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Graco Reactor 2 and is the answer not in the manual?

Graco Reactor 2 Specifications

General IconGeneral
BrandGraco
ModelReactor 2
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals