Shutdown
Shutdown
Immediate Shutdown
NOTICE
To avoid system damage, follow daily shutdown
procedure. Use only for immedia te shutdown.
For immediate shutdown, press:
Daily Shutdown
NOTICE
Proper system setup, startup, and shutdown
procedures are critical to electrical equipment
reliability. The following procedures ensure steady
voltage. Failure to follow these procedures will
cause voltage fluctuations that can damage
electrical equipment and v oid the warranty.
1. Press to stop the pumps.
2. Turn off al l heat z ones.
3. Set PRE SSURE RELIEF/SPRAY valves (SA,
SB) to PRESSURE RELIEF/CIRCULATION
.
4. Relieve pressure. See
Pressure Relief Procedure, page 69.
5. Press
to park th e Component A Pump. The
park operation is complete when green dot goes
out. Verify the park o peration is complete before
moving to next step.
6. Press to deacti vate the system.
7. Turn off the air compressor, air dryer, and
breathing air.
332636D 67