Setup
22 311075V
a.
Lift hose rack. Remove tank A
cover and pour ISO into tank A
(red side, with desiccant filter in
cover). Replace cover .
Desiccant filter is blue when fresh, and
turns pink when saturated. Be sure
shipping plugs are removed from open-
ings on desiccant filter.
b.
Remove tank B cover and pour
resin into tank B (blue side).
Replace cover .
.
Add thin coating of grease lubricant to tank o-ring if lid is difficult
to assemble to tank.
1
TI7017a
1
TI7018a
1
10.
Purge air and flush fluid from
lines
a.
Remove both recirculation tubes
(P) from the tanks and secure
each one in a dedicated waste
container.
b.
Set function knob to Stop/Park
.
c.
Plug in power cord(s). See T
ABLE
2, page 17.
d.
Open both pump fluid inlet valves
(V, shown in open position).
TI7022a
P
V