EasyManua.ls Logo

Graco Reactor E-10 - User Manual

Graco Reactor E-10
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Instructions - Parts List
For spraying or dispensing 1:1 mix ratio materials, including epoxies,
polyurethane foam, and polyurea coatings. For professional use only.
Not approved for use in European explosive atmosphere locations.
See page 4 for a list of models and maximum working pressures.
Important Safety Instructions
Read all warnings and instructions in
this manual. Save these instructions.
Nonheated Package, with 2K
Ultra-Lite
Gun and Cold
Spray disposable mixer
TI6989b
Heated
Package, with
Fusion
Gun
TI6987b
311075R
EN

Other manuals for Graco Reactor E-10

Questions and Answers

  • C
    Chad Page Jr.Aug 29, 2025
    How to fix no heat and heater indicator light off on Graco Reactor E-10?
    • J
      Jessica MooreAug 29, 2025
      If there's no heat and the heater indicator light is off on your Graco Paint Sprayer, try cycling the Heater Power off and then on to reset the circuit breaker. Also, with power on, check for continuity at clicks of heater control knob and at the overtemperature sensor. Check connections at the Heater Power switch.
  • M
    Margaret DouglasAug 29, 2025
    Why is the motor on my Graco Reactor E-10 Paint Sprayer overheating?
    • K
      Kylie AdamsAug 29, 2025
      If your Graco Paint Sprayer's motor is running too hot, it could be due to a few reasons. Try reducing the pressure duty cycle or the gun tip size. You might also want to move the Reactor E-10 to a cooler location. Allow one hour for cooling. Also, check the fan operation and clean the fan and motor housing.
  • M
    Michael WashingtonAug 28, 2025
    What to do if the air compressor does not run on my Graco Paint Sprayer?
    • J
      Jill HubbardAug 29, 2025
      If the air compressor on your Graco Paint Sprayer isn't running, here are a few things to check: * First, ensure the power is on. * If the voltage to the compressor is below 105 Vac for a 120 Vac system, try another outlet or reduce the length/increase the gauge of any extension cords. * Also, verify all power connections are secure. * If the compressor is humming, wait for the air pressure to bleed to zero. * If the electrical air unloader is stuck closed, replace it. * Ensure the ambient temperature is below 115°F (46°C); move the sprayer to a cooler area if needed.
  • J
    Jeffrey JonesAug 28, 2025
    How to troubleshoot pressure imbalance in Graco Reactor E-10 Paint Sprayer?
    • M
      Michael WhiteAug 28, 2025
      If your Graco Paint Sprayer shows a pressure imbalance, first check the fluid supply of the lower pressure component and refill if needed. If that doesn't solve it, reduce the pressure of the higher component by slightly turning the Recirc/Spray valve toward Recirc until the gauges show balanced pressures. Also, check the fluid inlet strainers and fluid filters at the gun. If using a disposable mixer gun kit, clean or change the restrictor at the mixer manifold.
  • T
    Thomas GonzalezAug 31, 2025
    What to do for Transducer B Failure on Graco Reactor E-10?
    • K
      Kelly JohnsonSep 1, 2025
      To address a Transducer B Failure on your Graco Paint Sprayer, first check the transducer B electrical connection. If the issue persists, reverse the A and B transducer electrical connections at the board. If the error moves to transducer A, replace transducer B.
  • L
    Lisa NavarroAug 27, 2025
    What to do if I have a fluid leak in the pump packing nut area of my Graco Reactor E-10 Paint Sprayer?
    • P
      Peggy AdkinsAug 27, 2025
      If you notice a fluid leak in the pump packing nut area of your Graco Paint Sprayer, it's likely due to worn throat seals, which you should replace.
  • N
    Nathan KnappAug 27, 2025
    What to do if pressures are not balanced when running Graco Paint Sprayer?
    • P
      pbrownAug 27, 2025
      If the pressures are not balanced when running your Graco Paint Sprayer, but pressure is generated and holds on both strokes, it could be due to unequal viscosities. Try changing the temperature setting to balance the viscosities. You might also need to change the restrictor at the mix point to balance back pressure. Another possibility is a restriction on one side, so clean the mix module or restrictor at the mix manifold. Finally, consider cleaning the gun check valve screens.
  • A
    Andrea GuerraAug 27, 2025
    What to do if Graco Reactor E-10 Paint Sprayer pressure doesn’t hold when stalled against gun in spray mode?
    • K
      Kimberly JacksonAug 27, 2025
      If the pressure doesn't hold when stalled against the gun in spray mode, it could be due to a leaking Recirc/Spray valve (repair it), a leaking piston valve or intake valve in the displacement pump (repair), or a leaking gun shutoff (repair).
  • B
    billy66Aug 27, 2025
    What to do if one side doesn’t come up to pressure in spray mode on Graco Reactor E-10 Paint Sprayer?
    • A
      Allison McdanielAug 27, 2025
      If one side isn't reaching the correct pressure in spray mode, the Recirc/Spray valve might be dirty or damaged; clean or repair it. Also, check if the fluid inlet strainer is plugged and clear it. A plugged or stuck-open pump intake valve could also be the cause; clean the pump intake valve.
  • K
    Katrina LopezAug 26, 2025
    What to do if Graco Reactor E-10 Paint Sprayer pump output low?
    • K
      Kimberly BushAug 26, 2025
      If you're experiencing low pump output, consider these possibilities: * The fluid inlet strainer might be plugged - clear it. * The disposable mixer could be plugged - clean or replace it. * The piston valve or intake valve in the displacement pump may be leaking or plugged - check the valves.

Summary

Related Manuals

Systems

Models

Warnings

ELECTRIC SHOCK HAZARD

General warnings about electrical hazards and precautions to prevent electric shock during operation and servicing.

TOXIC FLUID OR FUMES HAZARD

Hazards associated with toxic fluids and fumes, emphasizing proper PPE and handling.

PERSONAL PROTECTIVE EQUIPMENT

Requirements for wearing appropriate protective equipment to prevent serious injury during operation and servicing.

Overview

Slow Recirculation

Describes the function and use of slow recirculation mode for temperature transfer and heating.

Fast Recirculation

Explains the use of fast recirculation for higher flow rates and tank heating.

Pressure Adjust

Details the automatic pressure adjustment feature for dispensing and spraying.

Component Identification

Controls and Indicators

Motor;Pump Control Function Knob

Explains the function knob used to select operational modes like Stop/Park, Recirculation, and Pressure Adjust.

STATUS Indicator

Describes the status indicator light's function for indicating operational status and error codes.

Setup

Locate Reactor E-10

Instructions for properly positioning the Reactor E-10 unit on a level surface and avoiding rain exposure.

Electrical requirements

Guidelines for connecting the unit to the correct power source and ensuring proper electrical installation.

Ground system

Importance of grounding the equipment to prevent static and electric shock hazards.

Startup of Heated Units

Heatup Guidelines

Heat Management Tips

Spraying;Dispensing

Set function knob to Stop;Park

Initial step to set the function knob to the Stop/Park position before spraying.

Set Recirc;Spray valves to Spray.

Instructions to set the recirculation/spray valves to the spray position for operation.

Turn function knob to Pressure Adjust

How to adjust the function knob to set the desired fluid pressure for spraying.

Check fluid pressure gauges...

Verifying pressure balance between components A and B using gauges before spraying.

Open gun fluid manifold valves...

Procedure for opening gun fluid manifold valves on impingement mix guns for spraying.

Pause (Heated Units)

Engage piston safety lock or trigger safety lock.

Engaging safety locks on the gun to pause operation safely.

Set function knob to Slow Recirc

Setting the function knob to Slow Recirc to maintain temperature during a break.

Set Recirc;Spray valves to Recirc...

Setting valves to Recirc to bring temperatures back up after a pause.

Refilling Tanks

Instructions for safely refilling fluid tanks while maintaining system pressure.

Pressure Relief Procedure

Engage piston safety lock or trigger safety lock.

Engaging safety locks on the gun as the first step in relieving system pressure.

Set function knob to Stop;Park

Setting the function knob to Stop/Park as part of the pressure relief process.

Turn Recirc;Spray valves to Recirc.

Turning valves to Recirc to dump fluid back to tanks and drop gauge pressure.

Shutdown

Follow all steps of Pressure Relief Procedure...

Recommends following the pressure relief steps before shutting down the unit for breaks.

If using an impingement mix gun...

Specific shutdown step for impingement mix guns to keep internal parts clean.

Shut off Heater Power...

Turning off the heater power for heated units as part of the shutdown procedure.

Maintenance

Flushing

Engage piston safety lock or trigger safety lock.

Engaging safety locks as the initial step for flushing the equipment.

Set function knob to Stop;Park

Setting the function knob to Stop/Park during the flushing process.

Shut off Heater Power...

Turning off heater power for heated units to allow the system to cool during flushing.

Remove recirculation tubes...

Removing recirculation tubes and placing them in waste containers for flushing.

Turn Recirc;Spray valves to Recirc.

Setting the recirculation/spray valves to Recirc to begin the flushing sequence.

Set function knob to Fast Recirc

Using Fast Recirc to pump solvent or new fluid through the system.

Troubleshooting

Status Codes

Explanation of how to interpret status codes by counting the blinks of the status indicator (ST).

Status Code 1 and 2 Settings

Troubleshooting Chart

Repair

Before Beginning Repair

Critical safety precautions and preparation steps before starting any repair work on the equipment.

Removing Supply Tanks

Step-by-step instructions for safely removing the fluid supply tanks from the unit.

Recirc;Spray Valves

Displacement Pump

Control Module

Change Display Temperature Units (°F;°C)

How to switch temperature displays between Fahrenheit and Celsius.

Calibrate Temperature Displays

Procedure to adjust calibration screws for accurate temperature readings on the displays.

Replace Function Knob;Potentiometer

Control Board

Fluid Heaters (if supplied)

Pressure Transducers

Drive Housing

Cycle Counter Switch Replacement

Electric Motor

Motor Brushes

Fan

Parts

Heated Proportioners

Part numbers and descriptions for heated proportioner models.

Nonheated Proportioner

Part numbers and descriptions for nonheated proportioner models.

Suggested Spare Replacement Parts

All Units

List of common spare parts recommended for keeping on hand for all units.

Heated Units Only

List of specific spare parts recommended for heated unit models.

Dimensions

Technical Data

Graco Standard Warranty

Graco Information

Contact information and resources for obtaining the latest product information and support from Graco.

Graco Reactor E-10 Specifications

General IconGeneral
BrandGraco
ModelReactor E-10
CategoryPaint Sprayer
LanguageEnglish

Related product manuals