EasyManua.ls Logo

Graco Reactor H-XP3 Elite - Hydraulic Drive System

Graco Reactor H-XP3 Elite
110 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting
Hydraulic Hydraulic
Hydraulic
Drive Drive
Drive
System System
System
Beforeperforminganytroubleshootingprocedures:
1.FollowPressureReliefProcedure,page47.
2.TurnthemainpowerswitchOFF.
3.Allowequipmenttocool.
Trytherecommendedsolutionsintheordergivenfor
eachproblem,toavoidunnecessaryrepairs.Also,
determinethatallcircuitbreakers,switches,and
controlsareproperlysetandwiringiscorrectbefore
assumingthereisaproblem.
NOTE: NOTE:
NOTE:
Motorstartupisdelayedamaximumof5
secondsfromthelasttimethemotorwasturnedoff
toreducethechanceofthemotoroverheating.
PROBLEM PROBLEM
PROBLEM
CAUSE CAUSE
CAUSE
SOLUTION SOLUTION
SOLUTION
Looseconnectionsand/orcontactor
(CT01)isnotclosing.
Checkwiringbetweenthefollowing
components:
HCMandcontactorCT01
HCMandfusesF11/F12
DamagedHCM.ReplaceHCM.
Looseconnectionsand/orcontactor
(CT01)isclosing.
Checkwiringbetweenthefollowing
components:
motorjunctionboxandCB12
CB12
contactCT01andmain
disconnectswitch(orterminal
blocksTB06andTB09)
Electricmotorwillnotstartorstops
duringoperation.
Circuitbreakertripped.ResetCB12withintheelectrical
enclosureaftercon󰘰rmingwiringis
correctanditsinsulationisintact.
36 334946H

Table of Contents