Repair
Flush Flush
Flush
Inlet Inlet
Inlet
Strainer Strainer
Strainer
Screen Screen
Screen
Theinletstrainers󰘰lteroutparticlesthatcanplugthe
pumpinletcheckvalves.Inspectthescreensdailyas
partofthestartuproutine,andcleanasrequired.
Isocyanatecancrystallizefrommoisture
contaminationorfromfreezing.Ifthechemicalsused
arecleanandproperstorage,transfer,andoperating
proceduresarefollowed,thereshouldbeminimal
contaminationoftheA-sidescreen.
Note
CleantheA-sidescreenonlyduring
dailystartup.Thisminimizesmoisture
contaminationbyimmediately󰘱ushing
outanyisocyanateresidueatthestartof
dispensingoperations.
1.Closethe󰘱uidinletvalveonthey-strainerinlet
andshutofftheappropriatefeedpump.This
preventsmaterialfrombeingpumpedwhile
cleaningthescreen.
2.Placeacontainerunderthestrainerbasetocatch
drainoffwhenremovingthestrainerplug(C).
3.Removethescreen(A)fromthestrainer
manifold.Thoroughly󰘱ushthescreenwith
compatiblesolventandshakeitdry.Inspectthe
screen.Nomorethan25%ofthemeshshould
berestricted.Ifmorethan25%ofthemeshis
blocked,replacethescreen.Inspecttheo—ring
(B)andreplaceasrequired.
4.Ensurethepipeplug(D)isscrewedintothe
strainerplug(C).Installthestrainerplugwiththe
screen(A)ando—ring(B)inplaceandtighten.
Donotovertighten.Letthegasketmaketheseal.
5.Openthe󰘱uidinletvalve,ensurethatthereare
noleaks,andwipetheequipmentclean.Proceed
withoperation.
334946H 51

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Graco Reactor H-XP3 Elite and is the answer not in the manual?

Graco Reactor H-XP3 Elite Specifications

General IconGeneral
BrandGraco
ModelReactor H-XP3 Elite
CategoryPaint Sprayer
LanguageEnglish

Related product manuals