Removal and Installation of Electrode
3A1320L 17
2. Replace thermopile (7).
3. Install gas pilot mounting plate (319) to gas burner
mounting plate (18). Connect ground lead wire
(244).
4. Connect gas pilot line (71) to flared adapter (421).
5. Pull electrode wire through wire sleeving.
6. Connect electrode lead to pulse fire igniter.
7. Reconnect hose and turn LP-gas tank valve ON.
8. Check for gas leaks at final assembly (see Opera-
tion manual).
ThermoLazer 300TC/ProMelt Only
ti25746a
ThermoLazer 300TC/ProMelt Only
ThermoLazer 300TC/ProMelt