Kettle Gas Regulator Replacement
3A1320L 25
Kettle Gas Regulator Replacement
ThermoLazer 200/200TC
Removal
1. Close propane tank valve.
2. Disconnect gas supply hose (a) from propane tank.
3. Disconnect gas supply hose (a) from manifold (e).
Installation
1. Apply pipe sealant and connect gas supply hose (a)
to manifold (e).
2. Connect gas supply hose (a) to propane tank (a).
3. Open propane tank valve.
4. Check for leaks.
5. Verify gauge PSI. Gauge should read 3 PSI
± 1. If
higher than 4 PSI, slightly open torch valve and
recheck.
F
IG. 1