Setup
18 3A9095C
11. Place suction tube with drain tube in
grounded metal pail partially filled with
flushing fluid. See Grounding, page 13.
NOTE: Check flushing fluid for compatibility
with material that is to be sprayed. A
secondary flush with a compatible fluid may
be necessary. Water for latex paint or mineral
spirits for oil-based paint.
12. Turn ON/OFF switch to ON position.
13. Turn prime valve horizontal. Disengage
trigger lock.
14. Turn pressure control up until sprayer
begins to run.
15. Hold a metal part of the spray gun firmly
to a grounded metal pail. Trigger gun
and flush for one minute.
16. Turn ON/OFF switch to OFF position.
17. Engage trigger lock.
18. Sprayer is now ready for startup.